型 号 | 流 量(L/H) | 压 力(Mpa) | 柱塞直径(MM) | 行程(MM) | 泵速(MIN-1) | 功率(KW) | 进口口径(MM) | 重量(KG) |
JYZR-20/30 | 20 | 30 | 16 | 30 | 96 | 1.5 | 8 | 100 |
JYZR-24/20 | 24 | 20 | 144 | 1.1 | ||||
JYZR-28/25 | 28 | 25 | 18 | 1.5 | ||||
JYZR-35/10 | 35 | 10 | 1.1 | 10 | ||||
JYZR-35/20 | 35 | 20 | 20 | 1.5 | ||||
JYZR-40/10 | 40 | 10 | 1.1 | |||||
JYZR-45/15 | 45 | 15 | 22 | 1.5 | ||||
JYZR-50/10 | 50 | 10 | 1.1 | |||||
JYZR-75/16 | 75 | 16 | 25 | 1.5 | ||||
JYZR-100/12 | 100 | 12 | 30 | 1.1 | ||||
JYZR-120/5.0 | 120 | 5 | 1.5 | |||||
JYZR-130/10 | 130 | 10 | 32 | 1.1 | 12 | |||
JYZR-150/8.0 | 150 | 8 | 36 | 1.5 | ||||
JYZR-175/5.0 | 175 | 5 | 1.1 | |||||
JYZR-200/6.0 | 200 | 6 | 40 | 1.5 | ||||
JYZR-250/5.0 | 250 | 5 | 45 | 1.1 | ||||
JYZR-270/4.0 | 270 | 4 | 1.5 | |||||
JYZR-300/4.5 | 300 | 4.5 | 50 | 1.1 | ||||
JYZR-330/4.0 | 330 | 4 | 1.5 | |||||
JYZR-400/2.0 | 400 | 2 | 55 | 1.1 | ||||
JYZR-450/2.5 | 450 | 2.5 | 60 | 1.5 | 17 | |||
JYZR-480/1.5 | 480 | 1.5 | 1.1 | |||||
JYZR-630/1.0 | 630 | 1 | 1.5 |
JYZR型液压隔膜式计量泵型隔膜式计量泵|故障原因分析及排除方法
序 号 | 故障特征 | 故 障 原 因 | 排 除 方 法 |
1 | 不排液 | 1. 吸入高度太高 2. 吸入管道阻塞 3. 吸入管道漏气 | 1. 降低安装高度 2. 清洗疏通吸入管道 3. 压紧或更换密封垫片 |
2 | 排液量不够 | 1. 吸入管道局部阻塞 2. 吸入或排出阀内有异物卡阻 3. 泵阀磨损关闭不严 4. 转速不足 | 1. 疏通吸入管道 2. 清洗吸排阀 3. 修理或更换阀件 4. 检查电机和电压 |
3 | 排出压力不稳定 | 1. 吸入或排出阀内有杂物卡阻或漏气 2. 管道未设置背压阀 | 1. 清除吸、排阀内的杂质 拧紧螺丝消除漏气 2. 增设背压阀 |
4 | 计量精度不够 | 1. 柱塞密封填料漏液 2. 吸入或排出阀磨损 3. 电机转速不稳定 4. 调节手轮移位 | 1. 调整或更换密封填料 2. 更换吸排阀 3. 稳定电源频率和电压 4. 校准并固定 |
5 | 运转中有冲击声 | 1. 转动零件松动或严重磨损 2. 吸入高度过高 3. 吸入管道漏气 4. 介质中有空气 5. 吸入管径太少 6. 排出压力过高 | 1. 拧紧有关螺丝或更换新零件 2. 降低安装高度 3. 压紧吸入法兰或螺母 4. 排除介质中的空气 5. 增大吸入管径 6. 降低压力 |